Hourly volume
— m³
— vs. previous hour



















Controllers and I/O modules, IQ-SENSE LoRaWAN wireless transmitters, SCADA and MES systems — from the sensor to the manager’s screen.
Illustration. Names and data are fictitious.
Analytics, utilization rate, reports, rounds and calibrations
Process mimic diagrams, alarms, trends and site map in real time
C, B and D series controllers, distributed I/O modules, network adapters, gateways and switches
Sensors and wireless transmitters — field level
01 · MESProduction analytics and reporting
Production volume per hour, day, month and year with the trend against the previous period.Hourly, daily, monthly and annual volume.
02 · SCADAReal-time dispatch control
A process mimic diagram with current parameter values: the asset state is available without a site visit.A process mimic diagram with current parameter values.
How it works together
Field level: on-site devices measure parameters and transmit them over LoRaWAN.
Mimic diagrams, site map and plant-wide summaries: asset state without site rounds.
A parameter crosses its setpoint: the alert is addressed to whoever is in charge of that part of the site.
Remote commands to Amber ecosystem devices with execution confirmation.
Alerts, sensor trends, inspection and calibration logs: a complete history of events and states.
Field level: on-site devices measure parameters and transmit them over LoRaWAN.
Mimic diagrams, site map and plant-wide summaries: asset state without site rounds.
A parameter crosses its setpoint: the alert is addressed to whoever is in charge of that part of the site.
Remote commands to Amber ecosystem devices with execution confirmation.
Alerts, sensor trends, inspection and calibration logs: a complete history of events and states.
An analytics and operations control center for the enterprise.
03 · PLC · SignalsSignal I/O modules



Select a device on the left or right — we will show step by step where its signal goes.
| Signal type | Specifications | C seriesMain DIN-rail product line | B seriesBoard-level modules for compact solutions | D seriesRedundancy for critical systems |
|---|---|---|---|---|
| 8–16 channels, PNP/NPN, 24 VDC, pulse counting | CT-121FCT-1228 | BT-124F | DT-121F | |
| 16 DO 24 VDC / 0.5 A; 4 relays 2 A @ 250 VAC | CT-222FCT-2794 | BT-222F | DT-221F | |
| 8 DI + 8 DO on one module | — | — | DT-623F | |
| 8 channels: 0–10 V, ±10 V, 0/4–20 mA; 16 bit | CT-3168CT-3238 | BT-3238 | DT-3168 | |
| Pt100 (0.1%); thermocouples J, K, E, T, S, R, B, N | CT-3734CT-3844 | BT-3714 | DT-3804 | |
| 0–10 V, ±10 V, 0/4–20 mA; 16 bit | CT-4154CT-4238 | BT-4234 | DT-4234 | |
| Encoders 24 V / 5 V; RS-485/232/422, Modbus RTU/ASCII | CT-5112CT-5142CT-5321 | BT-5312 | — |
03 · PLC · ControlControl program per IEC 61131-3































IO MODULE-C3351
IO MODULE-B2341
IO MODULE-DU03L
03 · PLC · ConnectivityIntegrating the station into the plant networkGateway, switch and chassis — in the catalog


















Profinet IO · CN-8032-L
Modbus TCP · BN-8031
EtherCAT · DN-8033
04 · IQ-SENSEWireless telemetry over LoRaWAN
Device readings are delivered to Amber over LoRaWAN automatically.
Devices transmit data to Amber over LoRaWAN. The LoRaWAN network is deployed separately and is not included in the Amber scope of supply.
Commands to the device with delivery confirmation.
A new device type is connected without changing the software: packet parsing, commands and alarm rules are defined in the interface.
01 08 5A 00 D6 57Device configuration from a browser over Bluetooth: parameters and firmware updates.
The system and all data are hosted on the customer’s server. No connection to the vendor is required for operation.
Permissions by section and asset: an area supervisor sees their area, management sees the whole enterprise.
External systems receive data from Amber via Modbus TCP and the REST API.
Russian, English and Uzbek, light and dark themes. Runs in a browser, including on mobile devices.
A new type of LoRaWAN device is connected without changing the software: packet parsing, commands and alarm rules are configured in the interface.
Controllers, I/O modules and network equipment: a catalog of 35 items, C, B and D series.
| Code | Name | Key specs | Series |
|---|---|---|---|
| 01 · Controllers (PLCs) | |||
| Programmable logic controller | IEC 61131-3 · 1 MB program memory · up to 1024/1024 bytes | C | |
| Programmable logic controller | CODESYS · IEC 61131-3 · 5 programming languages | B | |
| Programmable logic controller | AIOSYS · IEC 61499 and IEC 61131-3 · LD, ST and C | D | |
| 02 · Network interfaces and adapters | |||
| Profinet network adapter | Profinet IO (Slave) · 2-port Ethernet switch · up to 32 expansion modules | C | |
| Modbus-TCP network adapter | Modbus-TCP Server · 2 Ethernet ports 10/100 Mbit/s · up to 8192 bytes | B | |
| EtherCAT network adapter | EtherCAT · input data up to 1024 bytes · output data up to 1024 bytes | D | |
| 03 · Digital I/O modules | |||
| 16-channel digital input module | 16 DI channels · PNP (Sink) · 24 VDC | C | |
| 8-channel digital input module | 8 DI channels · NPN (Source, active low) · 24 VDC | C | |
| 16-channel digital output module | 16 DO channels · PNP (Source, active high) · up to 0.5 A per channel | C | |
| 4-channel relay output module | 4 relay channels · 2 A @ 250 VAC | C | |
| 16-channel universal digital input module | 16 DI channels · NPN/PNP (Source/Sink) · 24 VDC | B | |
| 16-channel digital output module | 16 DO channels · PNP · 24 VDC / 0.5 A per channel | B | |
| 16-channel digital input module with redundancy | 16 DI channels · PNP type · with redundancy | D | |
| 16-channel digital output module with redundancy | 16 DO channels · NPN (active low) · with redundancy | D | |
| Combined digital I/O module | 8 DI channels (PNP/NPN) · 8 DO channels (PNP, 24 VDC) | D | |
| 04 · Analog I/O modules | |||
| 8-channel voltage input module | 8 AI channels · 0–5 VDC / 0–10 VDC · 16-bit ADC | C | |
| 8-channel current input module | 8 AI channels · 0–20 mA / 4–20 mA · 16 bit | C | |
| 4-channel RTD module | 4 RTD channels (Pt100) · basic accuracy 0.1% | C | |
| 4-channel thermocouple module | 4 TC channels · types J, K, E, T, S, R, B, N · accuracy 0.3% | C | |
| 4-channel voltage output module | 4 AO channels · 0–5 VDC / 0–10 VDC · 16-bit DAC | C | |
| 8-channel current output module | 8 AO channels · 0–20 mA / 4–20 mA · 16 bit | C | |
| 8-channel current input module | 8 AI channels · 0–20 mA / 4–20 mA · 16 bit | B | |
| 4-channel current output module | 4 AO channels · 0–20 mA / 4–20 mA · 16 bit | B | |
| 4-channel RTD temperature measurement module | 4 RTD channels (Pt100) · accuracy 0.1% | B | |
| 8-channel voltage input module with redundancy | 8 AI channels · 0–5 VDC / 0–10 VDC · with redundancy | D | |
| 4-channel thermocouple module with redundancy | 4 TC channels · J, K, E, T, S, R, B, N · with redundancy | D | |
| 4-channel current output module with redundancy | 4 AO channels · 0–20 mA / 4–20 mA · with redundancy | D | |
| 05 · Special and communication modules | |||
| 2-channel encoder module (24V) | 2 channels (24V) · quadrature decoding · 2 DI / 2 DO | C | |
| 2-channel differential encoder module (5V) | 2 channels (5V Differential) · quadrature decoder · 2 DI | C | |
| 1-channel communication module | 1 channel (RS485/RS232/RS422) · Modbus RTU/ASCII (Master/Slave) | C | |
| 2-channel RS485 module | 2 independent RS485 interfaces · Modbus RTU/ASCII · Free port | B | |
| 06 · Network equipment, gateways and chassis | |||
| Modbus to Profinet protocol converter | 2 serial ports · Profinet IO · up to 50 commands/slots | — | |
| Industrial Ethernet switch (5-16 ports) | 16 Fast Ethernet ports · 10/100 Mbit/s | — | |
| 64-channel chassis/base module with display | up to 64 I/O channels · status display | B | |
| 32-channel chassis/base module with display | up to 32 I/O channels · information display | B | |
No items match this combination.
Send us your equipment list — we will show how it will appear in the system.
You viewed: . Mention this part number when you write to us.
Address — we will add yoursMon–Fri, business hours — we will add yours
This information is for reference only. Capabilities depend on the system version. Screens on this site are illustrations with fictitious data. © Amber, 2026.